Discuss a project

Choosing a CDMO for an inhalation product is not like choosing one for a tablet

Choose an inhalation CDMO on how well it controls the things that decide inhaled product performance, not on general manufacturing capacity. With a tablet, the dose reaches the patient almost regardless of particle shape. With an inhaled product, however, the particles themselves, the device and the filling process together determine whether the dose reaches the lung. In practice, look for five things:

  1. Particle engineering capability, such as spray drying or jet milling, that can design size, morphology and density for deposition.
  2. In-house performance testing of the powder and device together.
  3. Precise powder device filling.
  4. Experience with your molecule type, including biologics if relevant.
  5. A continuous route from formulation feasibility to GMP clinical supply, so that the process you optimise is the one you manufacture.

The rest of this article takes each of these in turn and ends with a shortlist checklist you can put to any inhalation CDMO.

Dry Powder Inhaler (DPI) device alongside a capsule which can be filled with spray dried powder as an inhaled formulation for pulmonary delivery

Why inhalation changes the CDMO selection criteria

The product is formulation plus device plus fill, not just a formulation

An inhaled dry powder product is not a formulation on its own. The engineered particles, the device that disperses them and the filling process that meters each dose all contribute to performance. Moreover, if one of the three is wrong, the other two cannot compensate. Your inhalation CDMO therefore needs to understand how particle, device and fill interact, not just how to make each part.

Where the dose deposits defines performance, not only what is in the dose

For an oral solid dose, the questions are largely about content, stability and release. For an inhaled product, the question is whether the dose reaches the intended region of the lung. The aerodynamic behaviour of the emitted particles, which depends on their size, shape and density, governs how far into the respiratory tract they travel. This shifts the selection question from can they make it? to can they design the particle, prove its performance in the device and reproduce it at GMP?

What carries over from oral solid dose selection, and what does not

Some of the criteria you would apply to any CDMO still matter. However, others are specific to inhalation and are where shortlists tend to separate.

CriterionTablet or capsule CDMOInhalation CDMO
GMP status and quality systemsEssentialEssential
Project management and communicationEssentialEssential
What decides product performanceLargely formulation and processingParticle properties, device and fill working together
Particle design for depositionRarely criticalCentral
Performance testingDissolution and contentPowder tested in the device
FillingRoutine stepCritical process step for dose delivery

For the general criteria, meanwhile, Upperton’s guidance on selecting your CDMO partner and on evaluating CDMO communication before you commit apply equally to inhaled programmes. The sections below therefore focus on what is different.

1. Particle engineering: can the inhalation CDMO design the particle, not just make the powder?

Spray drying versus jet milling for inhaled powders

Jet milling reduces the size of existing solid material, typically crystalline drug substance, and formulators often pair it with a coarser carrier. Spray drying builds particles from a solution or suspension, which gives more control over morphology and density and lets formulators incorporate excipients, or a biologic, within each particle. Neither is universally better; instead, the right choice depends on the molecule, the dose and the device.

Ask whether a prospective partner offers both, so you choose the technology to suit your molecule rather than the equipment the CDMO happens to own. Upperton’s particle engineering service tailors particle size, morphology and density using technologies including spray drying and jet milling, particularly for nasal and pulmonary products. Its spray drying service lists dry-powder inhalation development among its primary use cases, and our insight on developing inhaled formulations covers the approach in more detail.

Controlling size, morphology and density for deposition

Particle size alone is not the target. In addition, morphology and density affect how particles disperse from the device and behave in the airstream. So, when assessing a CDMO, ask:

  • Which particle attributes do they treat as critical for your product, and how do they measure them?
  • How do they link process parameters to particle attributes, and particle attributes to in-device performance?
  • Can they show how they have adjusted morphology or density, not just size, to improve performance?

Excipient choices for dispersibility

Upperton has published research on how L-leucine content influences the internal and external morphology of spray-dried particles. When you speak to a CDMO, ask what evidence it has for its excipient selections and whether that work is in-house.

2. Performance testing: does the inhalation CDMO test the powder in the device, in-house?

Why testing the powder alone is not enough

Characterising the bulk powder tells you about the powder. However, it does not tell you how a dose disperses when it leaves the device. In fact, the same powder can perform differently in different devices and at different patient inspiratory flows. A CDMO that tests the powder and device together can find these interactions early, while particle and device decisions can still change.

For instance, Upperton’s particle engineering includes performance testing for nasal and pulmonary deposition.

Questions to ask about deposition and aerodynamic performance testing

  • Which aerodynamic particle size and delivered dose tests do you run in-house, and which do you outsource?
  • Do you test with the powder filled into the intended device, at the intended fill weight?
  • How quickly can performance data feed back into the next formulation or process iteration?
  • Can you test across a range of device options before you lock the device?

Analytical methods that follow the product from development into GMP

Similarly, methods developed during feasibility should be capable of becoming the methods used for GMP release and stability. Ask when the CDMO qualifies and validates its methods, and whether the same analytical team supports development and manufacture. In-house formulation and analytical teams support Upperton’s GMP manufacturing, and our analytical method development page outlines that service.

3. Device filling: can your inhalation CDMO fill precisely at very low fill weights?

Why filling is a critical process step for DPIs

Above all, variability in fill weight translates directly into variability in the dose delivered to the patient. You should therefore assess filling as part of product development, not treat it as a final packaging step.

Capsule, blister and device-based formats: what to ask

  • Which device formats can you fill, and at which development stages?
  • What fill weights can you achieve reliably with a powder like mine, and what accuracy and precision data can you share?
  • Is the filling equipment used in development representative of the equipment used for GMP manufacture?
  • How do you handle powders that are cohesive, low density or moisture sensitive during filling?

Matching filling capability to device choice early

For example, a device that suits the powder is no help if the CDMO cannot fill it at the required fill weight and scale. For this reason, discuss filling capability at the same time as device selection. Upperton has published an information sheet on high precision powder device filling and has announced an expansion of its high precision filling capability at its Nottingham facility.

4. Molecule fit for your inhalation CDMO: small molecules, complex molecules and biologics

Stabilising biologics as dry powders for pulmonary delivery

Formulators can use spray drying to stabilise some biologics as dry powders for pulmonary delivery. Feasibility depends on the molecule and needs early formulation screening.

If your molecule is a biologic, also ask the CDMO for its experience of drying biologics, how it assesses activity and degradation after processing, and how biologic stability work links to particle engineering for deposition. Upperton’s spray drying service lists biologic stabilisation through drying among its primary use cases. We have published a webinar and a whitepaper on the formulation and delivery of spray-dried biologics for pulmonary dosage forms, and a whitepaper on the pulmonary delivery of complex molecules.

Handling limited API in early inhaled development

Early inhaled programmes often have very little drug substance available, while particle engineering and performance testing can both consume material. Therefore, ask how much API a feasibility programme will need, whether the CDMO can run screening at small scale, and how the CDMO prioritises experiments when material is scarce. Upperton’s insight on API challenges in early-stage formulation development discusses working with small amounts of API.

5. One inhalation CDMO from feasibility to GMP clinical supply

Pilot-scale equipment that mirrors GMP manufacture

First, ask whether development equipment is representative of the GMP equipment that will make your clinical batches. Likewise, Upperton’s formulation development uses pilot-scale equipment designed to mirror GMP manufacturing.

Tech transfer risk when particle engineering and filling sit at different sites

Splitting particle engineering, testing and filling across organisations or sites adds transfer steps. By contrast, when the team that engineers the particle also tests and manufactures it, nobody has to transfer process knowledge between sites. Upperton’s GMP manufacturing links particle design to downstream dosage-form development and GMP supply. For more on the trade-offs, see our articles on technology transfer on a one-site CDMO and our tech transfer approach.

Clinical supply from first-in-human onwards

Finally, check that the CDMO can manufacture your inhaled product under GMP for the clinical phases you plan, and that its facility holds the approvals your programme needs. Upperton’s clinical trial manufacturing handles oral solids, bulk dry powders, dry-powder inhalers, nasal suspensions and solutions, from first-in-human through Phase III, at a GMP facility described as MHRA-approved and Home Office-approved. Upperton also offers PulmoCraft™, a dedicated pulmonary offering, and showcased its integrated approach to inhalation at DDL 2025.

A shortlist checklist for your inhalation CDMO

Ten questions to put to every inhalation CDMO

  1. Which particle engineering technologies do you offer in-house, and how do you choose between them for a given molecule?
  2. Which particle attributes will you control, and how will you show their link to deposition?
  3. Which performance tests do you run in-house with the powder in the device?
  4. How quickly do performance results feed back into formulation and process changes?
  5. Which device formats can you fill, and at what fill weights and precision with a powder like mine?
  6. Is your development filling and processing equipment representative of your GMP equipment?
  7. What experience do you have with my molecule type, including biologics or complex molecules?
  8. How much API will feasibility need, and how will you work with limited material?
  9. Will formulation, particle engineering, testing, filling and GMP manufacture happen within one organisation, and if not, where are the hand-offs?
  10. Which clinical phases can you supply, and what approvals does your GMP facility hold?

Red flags in proposals

  • A proposal that treats filling as a packaging step rather than a development activity.
  • Performance testing on bulk powder only, with in-device testing outsourced or deferred.
  • A single particle engineering technology offered for every molecule, without a rationale.
  • Unclear hand-offs between particle engineering, filling and GMP manufacture.
  • No plan for how development methods and processes will carry into GMP clinical supply.
  • Biologic programmes with no early screening of stability through drying.

Shortlisting an inhalation CDMO? Download our Inhalation Drug Product Development information sheet, or talk to our pulmonary team about your molecule and device.

Inhalation CDMO FAQs

Inhaled product performance depends on particle properties, the device and the fill working together. Buyers judge a tablet CDMO largely on formulation and processing. An inhalation CDMO must also design particles for deposition, test powder in the device, and fill devices precisely.

It reduces risk. When the team that engineers the particle, for example by spray drying or jet milling, also tests and manufactures it, nobody has to transfer process knowledge between sites.

Formulators can use spray drying to stabilise some biologics as dry powders for pulmonary delivery. Feasibility depends on the molecule and needs early formulation screening.

Ask which device formats the CDMO can fill, what fill weights it can achieve with your powder, and whether the filling equipment used in development is representative of GMP manufacture.

In general, engage one early, ideally before you lock particle and device decisions, because the two are interdependent and hard to change later.

Upperton Pharma Solutions, based in Nottingham, offers pharmaceutical spray drying with dry-powder inhalation development among its primary use cases, alongside particle engineering, performance testing for pulmonary deposition and clinical trial manufacturing of dry-powder inhalers from first-in-human through Phase III.

Table of Contents

Related Posts

Let's discuss your next project

Get in touch with our team to learn more about our expertise and how our project managers can support your project at every stage of the development pipeline.

Explore our CDMO services

Contact Form

We provide fully integrated services across every stage of drug product development.

This field is for validation purposes and should be left unchanged.
Consent